You are not logged in.

Dear visitor, welcome to SPRINKLER TALK FORUM - You Got Questions, We've Got Answers. If this is your first visit here, please read the Help. It explains how this page works. You must be registered before you can use all the page's features. Please use the registration form, to register here or read more information about the registration process. If you are already registered, please login here.

PVCQuestionAsker

Unregistered

1

Saturday, December 5th 2015, 12:29pm

Cement Telescoping Portion of EV Span (slip) coupling

My sprinkler system had a cracked Tee connector which I replaced with a new Tee and 3 EZ span (slip) couplings (shown in pic) where one end of each coupling can telescope out. There doesn't seem to be any leaks now but when I turn on the water the pressure pushes one of the telescoping portion out. I am worried this could cause issues.
My question is whether there would be any issues or adverse effects if I cemented the telescoping portion in place so it doesn't move anymore when I turn on the sprinklers in this area.



Wet_Boots

Supreme Member

Posts: 5,240

Location: Metro NYC

2

Saturday, December 5th 2015, 2:27pm

You would be far better off replacing the whole shebang with regular glued fittings and one or two schedule 80 unions. Easy install, full strength, and zero movement.

{P. S. - if that is PVC pipe coming through a foundation wall, it can shear right off if the soil settles next to the house}

mrfixit

Moderator

Posts: 2,185

Location: USA

3

Saturday, December 5th 2015, 3:47pm

I agree. You need to start over. That tee will crack for sure.

You only needed one slip fix. The pipe on the south and one of the other two pipes you should use slip couplings with a bit of pvc pipe. Then attach the tee to those two pipes and a slip fix for the third pipe should be ok.

Rate this thread