You are not logged in.

peterheading

Starting Member

Posts: 1

Location: Australia

1

Tuesday, October 25th 2005, 5:03pm

Watering System Malfunction

I have a property with a Hardie Rain Jet HR6100 6 station automatic watering system installed. It currently has 5 of the 6 stations in use. Upon using it this past week, I have discovered that all 5 active stations begin watering at the one time as soon as the water supply is turned on.

Is this likely to be a faulty controller, a problem with some of the wiring or a solenoid issue?

Tom

Supreme Member

2

Wednesday, October 26th 2005, 5:57am

check the valves first, perhaps all the bleed screws are open?

Wet_Boots

Supreme Member

Posts: 5,199

Location: Metro NYC

3

Thursday, October 27th 2005, 2:43am

Also, if the bleed screws aren't the problem, try to reboot the controller. Unplug, remove backup battery, and let it power down. Many, but not all, solid-state controllers have a 'reset' tab or button, to help in this. Hardie was bought by Toro, and old products of theirs now carry the Irritrol name, if you're seeking manuals online.