You need to change the flow on your sprinkler zones. 35 gpm is a lot to expect from a 1 HP pump. The CJ101 is something you would be operating nearer to 20 gpm, in order to get the output pressures that would justify choosing a multistage centrifugal pump.
If the pump curve is showing, you will see the 100 foot mark on the output curve is at less than 30 gpm. 100 feet equals 43 psi, but that is not output pressure, since you have to account for the height of suction lift and friction losses in strainers and check/foot valves. 27 gpm at 40 psi might be more realistic, and that's before you have to subtract for the strainer self-cleaning.
This post has been edited 2 times, last edit by "Wet_Boots" (Sep 8th 2017, 7:27am)