I had a sprinkler system installed last year. It has 6 zones. The 5th zone has low water pressure.
I have done the following things:
Swapped Solenoid with known good valve - Known good valve still worked perfectly
Swapped diaphragm with known good valve - Known good valve still worked perfectly
The valves are Irritrol 2400T w/o flow
There are no areas of the yard that are extremely wet, or seem flooded.
When the zone is activated, it is not able to lift the heads and therefore just dribbles water. If I loosen the solenoid, the heads pop right up and work fine but they wont shut off when the timer is done. If I loosen the bleeder valve, the heads works fine, but water is leaking in the control box. I did notice that when I remove the solenoid the water pressure is extremely low compared to the valve beside it (see pictures).
I would appreciate any assistance that could be provided. I don't believe that I have a leak in the main pipe, as my yard is not soaking in any specific location. Also, Zone 6 (further distance from control box) is working fine.