Friday, October 30th 2015, 12:03pm

Author: Evergreen Sprinkler

Drilling through Cinder BLock Wall

Quoted from "jsbeckton" I don't think the water company will be too happy if I tie in outside since the meter is in my basement! Ahh gotcha. I wasn't aware that they put meters in the houses. I'm located in the Pacific Northwest and the meters are usually out by the street.

Tuesday, October 20th 2015, 6:08pm

Author: Evergreen Sprinkler

What about the Water Behind the Backflow?

I've never understood these diagrams that show the main water tie-in inside or under the house.... ( must be a warm climate thing) not a good idea in my opinion. We do our main and drain valves together outside between the water meter and the house. It does suck digging that 3-4 foot hole to get to the water line though.

Tuesday, October 20th 2015, 5:55pm

Author: Evergreen Sprinkler

Drilling through Cinder BLock Wall

Maybe this won't work for you...Around here we always tie in to the potable supply before gets to the house..?

Tuesday, October 20th 2015, 5:47pm

Author: Evergreen Sprinkler

hunter x core 600 ( Zones no AC power)

Have you verified that you have continuity from your stations to your common?

Tuesday, October 20th 2015, 5:22pm

Author: Evergreen Sprinkler

Help with Head Placement.

Quoted from "maximus20895" Make the link look like this: [u!rl='evergreensprinklersupply.com']Evergreen Sprinkler Supply[/u!rl] Just remove the "!'s" in the beginning and end! Thanks!!

Monday, October 19th 2015, 10:41am

Author: Evergreen Sprinkler

Help with Head Placement.

Quoted from "maximus20895" BTW: Fix your URL so it works properly Thanks for pointing that out. I havent figured out to fix it yet?

Monday, October 19th 2015, 10:28am

Author: Evergreen Sprinkler

hydro rain valve type

Red Barrons Good valves! They don't make them like they use to anymore! Use part numbers R-1359 or the SPK-HR1 kit. Hopefully Irritrol never decides to discontinue these parts.

Thursday, October 15th 2015, 1:04pm

Author: Evergreen Sprinkler

Leaking

That could be the 1/4" test cock... look for a flat head screw slot and turn it to close the valve.

Thursday, October 15th 2015, 12:42pm

Author: Evergreen Sprinkler

Help with Head Placement.

The contractors around here usually double to triple the cost of materials for a labor cost.

Wednesday, October 7th 2015, 11:03am

Author: Evergreen Sprinkler

Zone not getting voltage but resistance is 27 ohms

Maybe it is a problem with the valve itself. The diaphragm could be bad. Some valves that are a reverse flow will fail closed when the diaphragm has a hole in it.

Friday, September 25th 2015, 9:42am

Author: Evergreen Sprinkler

1st Zone ALWAYS ON, even when controller is de-energized

The valves will usually be in a plastic valve box in the ground. You will have an electric valve for every zone on your clock. Once you find valve you can repair or replace it. You can search on youtube for a how to video. It sounds like a bad diaphragm if the valve is sticking open. That is a pretty easy fix.

Thursday, September 24th 2015, 1:00pm

Author: Evergreen Sprinkler

Drip System with Puddles Closer to the Valve

It depends on what kind of drip line was used. Does it have check valve emitters and is it pressure compensating? Does it puddle up after its off or while it's on? The difference in pressure may due to the station being too big and using too much drip line. If the line is over 200' in lenght you will start running out off water, specially if you have pressure regulators starting you out at a low pressure.

Thursday, September 24th 2015, 12:39pm

Author: Evergreen Sprinkler

Greys (LA) & PGP Glands

You won't get the same effect by turning the set screw down. The spray pattern will suffer. You might think about using the PGJ to get a shorter throw. The riser seals should last longer than that. There are a couple of factors that may be shortening the life span. The heads may be set too low and below grade causing them to draw in debris when then pop up and down. Second, you may have really sandy soil causing the seals to wear out faster. The only fix there would be to use a head with a stain...

Wednesday, September 16th 2015, 10:45am

Author: Evergreen Sprinkler

Front Lawn Sprinkler Design

Quoted from "6010fd12" Quoted from "Evergreen Sprinkler" You shouldn't need those full circles. If you plan to use the mp800sr heads I would just space them evenly every 10 feet. You should end up with 4 quarters and 4 halfs for a total gpm of 2.6. So something like this? These are all 10' except for the bottom right sprinkler that is 8' so I don't water the driveway. Yup. That looks good to me!

Friday, September 11th 2015, 10:51am

Author: Evergreen Sprinkler

One sprinkler head on zone with 3 heads does not pop up

Your leak may be bad enough that it is taking pressure from that head so it won't popup.

Friday, September 11th 2015, 10:48am

Author: Evergreen Sprinkler

NEWB Question

They could be anything..... a picture would help to identify them.

Friday, September 11th 2015, 10:44am

Author: Evergreen Sprinkler

Risers/Nozzles changing directions

Hunter SRS spray heads we re notorious for doing this. The only fix for this would be to replace the popup with a new one that has a good ratcheting riser. I like the Hunter pro spray or the Rainbird 1804.

Friday, September 11th 2015, 9:41am

Author: Evergreen Sprinkler

Rain Bird ESP 16-LX battery burned out, now display doesn't work

Quoted from "Dagobah" Quoted from "Evergreen Sprinkler" What's the process like to upgrade to a ESPME? You would just replace the complete controller.

Friday, September 11th 2015, 9:36am

Author: Evergreen Sprinkler

Front Lawn Sprinkler Design

You shouldn't need those full circles. If you plan to use the mp800sr heads I would just space them evenly every 10 feet. You should end up with 4 quarters and 4 halfs for a total gpm of 2.6.

Friday, September 11th 2015, 9:20am

Author: Evergreen Sprinkler

RE: RainBird RC1260

Quoted from "jwh" My, old as the hills, RainBird RC1260 just stopped working. It will not ad. nce, and the day control wheel spins freely, not advancing at all. If I manually move the controls from station to station the sprinklers turn on, but they will run endlessly if I don't turn them ahead. I am assuming I may not be able to fix this old controller. If that is true, what shall i get instead? I have 11 stations and do not need anything fancy - just something that turns on and off at the pre...