Tuesday, April 16th 2013, 5:56pm

Author: heschlie

Sprinkler nozzle not spraying to listed distances

Thanks for the vote of confidence there wet_boots, could you please elaborate for the amateur did wrong with this calculations? I did the bucket test for GPM at the valve, and also hooked a gauge up to get the PSI from the same valve, which the numbers are stated above. I was also worried that I had run into a flow problem but I turned the system down to 2 spray heads being active with no visible change between that and 6 heads (a flow change from 10.06gpm to 4.74gpm) I don't mean to sound overl...

Tuesday, April 16th 2013, 4:33pm

Author: heschlie

Sprinkler nozzle not spraying to listed distances

There is a slight slope, maybe 2" drop per 10' but even the one on higher ground going downhill I'm still only seeing just above 9'. I took apart the valve to check if anything was clogging it, but it looked clean. I also turned back on the other 4 heads and could not see a visible difference in spray. They are not misting or fogging, I can shoot a video if it will help. At this point, since I am not seeing any difference when adding the other heads back, I was thinking of respacing the heads an...

Tuesday, April 16th 2013, 1:31pm

Author: heschlie

Sprinkler nozzle not spraying to listed distances

Quoted from "Central Irrigation" Few thingds to check.... 1. Are the radius screws on the spray nozzles closed at all? 2. Is the valve that runs these spray heads a Flow Control model? 3. If the answer to 2. is yes....is the flow control fully open? 1 - They are fully opened 2 - Yep it is a flow control valve 3 - Yes the flow control is completely open There is noting in the body of the sprinkler that is adjustable correct? I am using the Rainbird 1804 SAM series.

Monday, April 15th 2013, 8:13pm

Author: heschlie

Sprinkler nozzle not spraying to listed distances

Hi All, I recently purchased and installed a system, or at least finished one zone so far, I purchased the Rainbird HE-VAN12 nozzles and I seem to be only getting ~9ft not 12ft radius. I checked each of the heads for contaminates, shut off all but 2 heads, and I'm still sitting with only about 9ft of distance. Some more info on the system: At the valves I am getting (Rainbird 100-ASVF): 42psi 15gpm Measured from an adjacent valve. I am using 3/4" sch40 PVC for the laterals, at a maximum distance...