Dear visitor, welcome to SPRINKLER TALK FORUM - You Got Questions, We've Got Answers. If this is your first visit here, please read the Help. It explains how this page works. You must be registered before you can use all the page's features. Please use the registration form, to register here or read more information about the registration process. If you are already registered, please login here.

Attention: The last reply to this post was 784 days ago. The thread may already be out of date. Please consider creating a new thread.

Message information
Message
Settings
Automatically converts internet addresses into links by adding [url] and [/url] around them.
Smiley code in your message such as :) is automatically displayed as image.
You can use BBCode to format your message, if this option is enabled.
Security measure

Please enter the letters that are shown in the picture below (without spaces, and upper or lower case can be used).

The last 5 posts

Wednesday, June 6th 2012, 6:52pm

by hi.todd

It could be that there was a rain sensor that has been inadvertently abandoned in the move.

This wire if cut or abandoned will kill the system.

Good Luck
:thumbsup: :thumbsup:

It may be a good time to call the guy.

Tuesday, June 5th 2012, 9:32am

by Wet_Boots

Consider the possibility of a wiring fault

Tuesday, June 5th 2012, 8:33am

by GatorGuy

"The system briefly sends the solenoids the correct 24..." Should be constant. Does it not stay on?
" one of the sprinklers in the yard is barely leaking" How long does it leak? Is it at the bottom of a slope? If so, could be line seepage, which is normal until the zone empties. Need head with check valve.

Tuesday, June 5th 2012, 3:43am

by mrfixit

Is there water to the system? Try turning on one of the valves manually at the valve. Turn the solenoid counter clockwise.
If not find the shut off valve and turn it back on.
----
If you have a master valve that could be the problem.

Monday, June 4th 2012, 11:07pm

by Zxdrew

New Old House - Hunter System - 2nd Round

I've got a Hunter SRC 900i. I can not get the system to turn on. Right before we moved into the house we had the fuse panel moved from inside the master closet to outside wall. Now the sprinkler system won't work. The only other electrical work done was gfci were installed in the garage and kitchen. Currently the box receives the right amount of power and has the right amount of water pressure. The system briefly sends the solenoids the correct 24v needed to kick them open, however none of them will actually turn a section on. Also one of the sprinklers in the yard is barely leaking. I replaced the head but the new head continues to leak. I turned the solenoid responsible for the value on then off but the slight leaking continues.

Before I call "the guy" I want to know if there is anything at all I can test or if y'all have any ideas of what can be wrong?

I'm going to try to replace a solenoid to see if they have all been burnt out somehow.