Dear visitor, welcome to SPRINKLER TALK FORUM - You Got Questions, We've Got Answers. If this is your first visit here, please read the Help. It explains how this page works. You must be registered before you can use all the page's features. Please use the registration form, to register here or read more information about the registration process. If you are already registered, please login here.
Attention: The last reply to this post was 4308 days ago. The thread may already be out of date. Please consider creating a new thread.
The last 7 posts
See if all the zone valves are of the same mfg'r and they have the same solenoids.... use those resistance readings as a guide to what those that don't work are.
Some solenoids today have resistances in the 25 ohm area and the older Richdel and Garden America solenoids, are in the 20 ohm area. In ANY case, replace soleoids that are 18 ohms or less in resistance.
b.
You test the zones for resistance, from zones to Common. Good ones show about 50 to 100 ohms resistance. The Fluke will have a special 'low voltage' ohms setting, for testing resistances. Use that, and compare readings between operational zones and faulty ones.
I have a fluke meter but how and where am i doing the testing
Get a test meter. Even a cheapie Radio Shack VOM is enough for simple resistance measurements.
ok and how do i go about doin the resistance testing, thanks
Short Circuit. Bad wiring. Bad solenoids. Old solenoids. (some perfectly functional solenoids from the 'good old days' draw too much current for some solid-state controllers) ~ Start checking resistances.
Electrical Surging
This is an existing System, there are 11 zones. This system is a rainbird system. Only 3 zones would work with the clock out off 11, Changed clock to a hunter pro-c 3 station clock with 3-3station modules to gove me the 11 zones. Now with new clock installed, i now have 8 of the 11 zones working electrical and the other 3 only working manually. There a 2 zones when programmed with time on the manual station setting will show on controller for a quick second and then go right to the next zone, will not even stay on long enough to test it, what might be the problem?? The third zone will stay on and show time but the valve will not come on, is this a switched wire on the valve or?? Any suggestion would greatly be appreciated, Thanks