Dear visitor, welcome to SPRINKLER TALK FORUM - You Got Questions, We've Got Answers. If this is your first visit here, please read the Help. It explains how this page works. You must be registered before you can use all the page's features. Please use the registration form, to register here or read more information about the registration process. If you are already registered, please login here.

Message information
Message
Settings
Automatically converts internet addresses into links by adding [url] and [/url] around them.
Smiley code in your message such as :) is automatically displayed as image.
You can use BBCode to format your message, if this option is enabled.
Security measure

Please enter the letters that are shown in the picture below (without spaces, and upper or lower case can be used).

The last 6 posts

Wednesday, July 18th 2018, 7:18am

by Wet_Boots

Consider replacing all the old W*M diaphragms, which will reset the clock on a key system component.

And yes, the diaphragm was next in the chain of diagnostics. A pro would have known by the look and feel of the old one that it was time for a new one, but that look and feel does not translate into words, hence the solenoid and exhaust port test.

Tuesday, July 17th 2018, 9:55pm

by jim_gaab

Exhaust port was clean. Although I didn't think a new diaphragm was needed, I was able to find a $7 replacement. Replacing the diaphragm did the trick. The old one didn't have a hole in it, but it was quite a bit harder than the new one.

Thank you very much for all of your help.

Sunday, July 15th 2018, 6:02am

by Wet_Boots

You can have a try at probing the "exhaust port" underneath the solenoid plunger with some bare wire. Any obstruction in that passageway can prevent a valve from opening.

Thursday, July 12th 2018, 8:50am

by jim_gaab

Thanks for the response and please excuse the delay.

After removing the plunger & spring, still no significant flow at the sprinklers.

Monday, July 9th 2018, 9:13am

by Wet_Boots

Turn off the water supply. Remove the solenoid plunger and spring from the problem valve. Turn the water back on. What result do you see?

Sunday, July 8th 2018, 11:07pm

by jim_gaab

33-year old weathermatic valve won't turn sprinklers on

33 year-old black plastic Weathermatic valve, 4 screws on top, round solenoid, looks like "silver bullet" but has no ribs on top of molded case and brass flow control "cross' on top, diaphragm has brass conical weight at bottom.

I've tried disassembling, flushing the valve, cleaning the diaphragm, using the manual flow control lever to activate, loosening the solenoid, running without the solenoid plunger. Diaphragm has no holes other than the 2 tiny ones that belong there. I orient the diaphragm correctly.

When I try to run it (even with the little manual lever on the side) I hear what sounds like lots of water running. The most I get out of the sprinklers is a VERY tiny trickle.

I thought that air might be trapped. I rotated the manual control open and closed 2-3 times.

Strangely, when I expected a solenoid problem, I swapped the solenoids with the solenoid from a working valve. Now neither valve is working. I did not disassemble the second valve (other than the solenoid). Again, when I try to run the second one with the little manual lever on the side) I hear what sounds like lots of water running but no resulting water at sprinklers.

I have a working valve on the same system, so I don't expect that there are any water pressure issues.

I was thinking it was a hardened diaphragm, but don't understand how that would cause the issue with the 2nd valve. Diaphragm seems hard to find. I'm totally stumped. Thanks, in advance, for any help you can provide.