You are not logged in.

Reply

Dear visitor, welcome to SPRINKLER TALK FORUM - You Got Questions, We've Got Answers. If this is your first visit here, please read the Help. It explains how this page works. You must be registered before you can use all the page's features. Please use the registration form, to register here or read more information about the registration process. If you are already registered, please login here.

Attention: The last reply to this post was 584 days ago. The thread may already be out of date. Please consider creating a new thread.

Message information
Message
Settings
Automatically converts internet addresses into links by adding [url] and [/url] around them.
Smiley code in your message such as :) is automatically displayed as image.
You can use BBCode to format your message, if this option is enabled.
Security measure

Please enter the letters that are shown in the picture below (without spaces, and upper or lower case can be used).

The last 3 posts

Monday, January 21st 2013, 9:53am

by George_Thomas (Guest)

Thanks Wet_Boots. That's the one thing that escaped my thought train: it was working prior to cutting the wires.

So I'll work from the solenoid back to the controller.

Sunday, January 20th 2013, 10:20pm

by Wet_Boots

Deal with this as purely an electrical problem in the wiring, since you seem to be saying the system was working prior to your cutting the wires.

Sunday, January 20th 2013, 2:58pm

by George_Thomas (Guest)

One zone quit working

Thirty-five-year-old Rain Bird Controller, 3 1-1/2" Rain Bird Valves, 1 1" Toro 230-06-04 Valve. While digging to replace a sprinkler head, I partially cut through the wire bundle leading from the controller.

Although I only cut one or two wires in the bundle of six or eight with the shovel, it was easier for me to cut the entire bundle, then solder the leads back together and wrap each wire and the bundle with black electricians tape. Since that time I've discovered that one zone out of my total of four does not work. That zone uses the original Toro 230 valve but has never caused a problem of any kind in the past. After finding the dead zone, I went back and checked my work on the wires and found them to all be intact.

The Rain Bird valves in my system have a stainless nut and washer on the bottom of the diaphragm which holds it together and when that breaks off, the zone won't come on except by using the bleed screw. Since those are the symptoms I'm having with the Toro 230 I opened it up to look at the diaphragm. I tried to get the diaphragm out but couldn't, and I didn't want to damage the diaphragm by prying on it if it still works. From the top of the diaphragm it appears the Toro 230 does not have such a screw holding it all together. Everything else inside appears to be OK so I cleaned it all and closed it back up.

When I cut the wires, the controller was still plugged in because I wasn't doing any electrical work but it was not active. Is it possible that the shovel cutting through one or two wires could have fried the solenoid? I haven't checked the solenoid yet, but I assume disconnecting it and checking for continuity would do the trick.

I believe someone on another site mentioned that the 250-06-04 valve solenoid is interchangeable with the 230, and if necessary the guts from the 250 could be swapped out with the 230 but I would like to confirm this to be true, if indeed it is the way to go. I would like to avoid having to change out the entire valve if I can.

Any help will be greatly appreciated.